• Low sound level
  • Low height
  • No vibration transmission
  • FRP Casing, free of maintenance and corrosion
  • Internals fully made in plastic materials
Model *Dissip.
K.w.
Empty Weight
Kg.
Service Weight Kg. Recirculation Pump
Kw.
Fan Power
Kw.
Long
mm.
Width
mm.
High
mm.
Dim. Drawing Plane
A-Card
Technical Feat.
EWK-C 144/2 26 650 1190 0.75 2.2 1220 1220 2320seleccionarseleccionar[-]
EWK-C 144/3 52 750 1290 0.75 2.2 1220 1220 2620seleccionarseleccionar[-]
EWK-C 144/4 73 900 1440 0.75 2.2 1220 1220 2620seleccionarseleccionar[-]
EWK-C 225/3 99 1180 2140 0.75 3.0 1534 1534 2660seleccionarseleccionar[-]
EWK-C 225/4 128 1345 2305 0.75 3.0 1534 1534 2260seleccionarseleccionar[-]
EWK-C 225/5 165 1575 2535 0.75 3.0 1534 1534 2960seleccionarseleccionar[-]
EWK-C 324/3 180 1485 2745 1.5 4.0 1825 1825 2890seleccionarseleccionar[-]
EWK-C 324/4 203 1756 3030 1.5 4.0 1825 1825 2890seleccionarseleccionar[-]
EWK-C 324/5 230 2075 3340 1.5 4.0 1825 1825 3190seleccionarseleccionar[-]
EWK-C 441/3 218 1780 3920 2.2 7.5 2140 2140 2940seleccionarseleccionar[-]
EWK-C 441/4 301 2085 4245 2.2 7.5 2140 2140 2940seleccionarseleccionar[-]
EWK-C 441/5 383 2440 4600 2.2 7.5 2140 2140 3240seleccionarseleccionar[-]
EWK-C 441/6 401 2850 5010 2.2 7.5 2140 2140 3540seleccionarseleccionar[-]
EWK-C 576/3 335 2205 4630 2.2 7.5 3020 2320 3365seleccionarseleccionar[-]
EWK-C 576/4 395 2554 5030 2.2 7.5 3020 2320 3365seleccionarseleccionar[-]
EWK-C 576/5 460 2960 5460 2.2 7.5 3020 2320 3740seleccionarseleccionar[-]
EWK-C 576/6 480 3430 5930 2.2 7.5 3020 2320 4040seleccionarseleccionar[-]
EWK-C 900/3 492 3380 8075 4.0 11.0 4125 2025 3780seleccionarseleccionar[-]
EWK-C 900/4 555 3850 8612 4.0 11.0 4125 2025 3780seleccionarseleccionar[-]
EWK-C 900/5 559 4385 9185 4.0 11.0 4125 2025 3980seleccionarseleccionar[-]
EWK-C 900/6 639 4995 9795 4.0 11.0 4125 2025 4280seleccionarseleccionar[-]
EWK-C 1260/3 754 5566 11360 2x4.0 15.0 4260 3040 4850seleccionarseleccionar[-]
EWK-C 1260/4 921 6359 12470 2x4.0 15.0 4260 3040 4850seleccionarseleccionar[-]
EWK-C 1260/5 1109 7265 13860 2x4.0 15.0 4260 3040 5130seleccionarseleccionar[-]
EWK-C 1260/6 1250 8300 14900 2x4.0 15.0 4260 3040 5260seleccionarseleccionar[-]
EWK-C 1800/3 1046 6570 15350 2x4.0 22.0 4100 4100 3990seleccionarseleccionar[-]
EWK-C 1800/4 1319 7610 17760 2x4.0 22.0 4100 4100 3990seleccionarseleccionar[-]
EWK-C 1800/5 1486 8810 20570 2x4.0 22.0 4100 4100 4300seleccionarseleccionar[-]
EWK-C 1800/6 1610 10200 23820 2x4.0 22.0 4100 4100 4590seleccionarseleccionar[-]

* Heat rejection at the following conditions: Tin: 35,0 ºC, Tout: 30,0 ºC, Twb: 24,0 ºC

WORKING PRINCIPLE: COOLING TOWERS

The fluid to be cooled (usually water) flows through the tubes of the coil without coming into direct contact with the external air, preventing dirt or pollution from entering the primary water circuit. The heat is transmitted from the fluid through the tube walls to the water, which is being continuously sprayed over the coil.

The fan situated at the top of the tower intakes air in counterflow to the water, thereby evaporating a small part of the re-circulating water, drawing off the necessary heat for evaporation and releasing it into the atmosphere. The rest of the water is re-circulated with a spray water pump from the basin to the spray nozzles. (Secondary circuits). A small quantity of heat is transmitted by convection to the external air, just as for an air cooler

  1. Sound Attenuator.
  2. Access ladder & Hand rail to the fan motor.
  3. Vibration Switch.
  4. Electric water control level in the Basin .
  5. Winter Pack (Thermostat & immersion heater)
  6. Two speed fan motors.