• Low sound level
  • Low height
  • No vibration transmission
  • FRP Casing, free of maintenance and corrosion
  • Internals fully made in plastic materials
  • Modular design
  • Integrated frame support
  • Epoxi coated fans
Model *Dissip.
kw
Empty Weight
kg
Service Weight
kg
Fan Power
kw
Long
mm
Width
mm
High
mm
Dim. Drawing Plane
DWG
Technical Feat.
WITHOUT MUFFLERS
EWK-D 225/2 349 718 1495 4,3 3191 1612 2470seleccionarseleccionar[-]
EWK-D 225/3 360 718 1495 5,3 3191 1612 2470seleccionarseleccionar[-]
EWK-D 225/4 379 718 1495 6,2 3191 1612 2470seleccionarseleccionar[-]
EWK-D 324/2 490 1010 2135 5,3 3585 1896 2535seleccionarseleccionar[-]
EWK-D 324/3 518 1010 2135 7.0 3585 1896 2535seleccionarseleccionar[-]
EWK-D 324/4 546 1010 2135 8,5 3585 1896 2535seleccionarseleccionar[-]
EWK-D 450/2 685 990* 2870* 7,1 4151 2209 2565seleccionarseleccionar[-]
EWK-D 450/3 720 990* 2870* 9,4 4151 2209 2565seleccionarseleccionar[-]
EWK-D 450/4 758 990* 2870* 11,4 4151 2209 2565seleccionarseleccionar[-]
EWK-D 680/2 1035 1500* 4300* 10,3 5183 2369 2600seleccionarseleccionar[-]
EWK-D 680/3 1088 1500* 4300* 13,6 5183 2369 2600seleccionarseleccionar[-]
EWK-D 680/4 1146 1500* 4300* 16,4 5183 2369 2600seleccionarseleccionar[-]
EWK-D 900/2 1275 2100* 5500* 12,9 6486 2092 2600seleccionarseleccionar[-]
EWK-D 900/3 1392 2100* 5500* 17,2 6486 2092 2600seleccionarseleccionar[-]
EWK-D 900/4 1517 2100* 5500* 20,6 6486 2092 2600seleccionarseleccionar[-]
WITH MUFFLERS
EWK-DA 225/2 349 1292 2069 4,4 4191 1612 3465seleccionarseleccionar[-]
EWK-DA 225/3 360 1292 2069 5,9 4191 1612 3465seleccionarseleccionar[-]
EWK-DA 225/4 379 1292 2069 7,3 4191 1612 3465seleccionarseleccionar[-]
EWK-DA 324/2 490 1650 2775 5,9 4585 1896 3550seleccionarseleccionar[-]
EWK-DA 324/3 518 1650 2775 8,0 4585 1896 3550seleccionarseleccionar[-]
EWK-DA 324/4 546 1650 2775 9,9 4585 1896 3550seleccionarseleccionar[-]
EWK-DA 450/2 685 2218 3736 7,9 5096 2209 3600seleccionarseleccionar[-]
EWK-DA 450/3 720 2218 3736 10,7 5096 2209 3600seleccionarseleccionar[-]
EWK-DA 450/4 758 1590 3580 13,0 5096 2209 3600seleccionarseleccionar[-]
EWK-DA 680/2 1035 3157 5881 11,4 6178 2369 3890seleccionarseleccionar[-]
EWK-DA 680/3 1088 3157 5881 15,4 6178 2369 3890seleccionarseleccionar[-]
EWK-DA 680/4 1146 3157 5881 18,9 6178 2369 3890seleccionarseleccionar[-]
EWK-DA 900/2 1275 3619 6833 14,5 7496 2092 3890seleccionarseleccionar[-]
EWK-DA 900/3 1392 3619 6833 19,7 7496 2092 3890seleccionarseleccionar[-]
EWK-DA 900/4 1517 3619 6833 24,5 7496 2092 3890seleccionarseleccionar[-]

*Heat rejection at the following conditions: Tin: 35,0 ºC, Tout: 30,0 ºC, Twb: 24,0 ºC

WORKING PRINCIPLE

Cooling towers bring a cold and dry air mass in counter-flow to hot water that comes from an industrial or air conditioning process. Part of this water evaporates, cooling the rest. The necessary heat for this is approx.597 Kcal/liter. The cold water produced is returned into the process to re-initiate the cycle. The equipment with this evaporative refrigeration principle are very important for energy efficiency in industrial processes.

The difference between the required cold water temperature and the wet bulb temperature (called cooling limit distance), is significant to determine the size of the tower. The smaller the cooling distance is, the bigger the interchanging surface is needed. The limit distance must be of at least 3-4º C.

In open cooling towers there is a close contact water-air, which is bigger thanks to the fill packings, that provide a big surface of exchange, and allow towers to be smaller.

  1. Sound attenuators for air inlet and outlet.
  2. Winter Pack (Thermostat & immersion heater)
  3. Frequency converters.
  4. Systems for water treatment