• Compact polyester casing
  • Plastic Internals
  • Low energy consumption
  • Easy maintenance
  • Broad range. (From 4 to 500 m3/h)
  • Modular design
  • Laminar and dripping fillings
Model *Dissip.
kw
Empty Weight
kg
Service Weight
kg
Fan Power
kw
Long
mm
Width
mm
High
mm
Dim. Drawing Plane
DWG
Technical Feat.
EWK 036/06 46 51 115 0.37 720 615 1745seleccionarseleccionar[-]
EWK 064/09 103 126 235 0.55 999,5 832 2225seleccionarseleccionar[-]
EWK 100/09 174 164 362 1.1 1300 1030 2641seleccionarseleccionar[-]
EWK 144/09 260 218 490 2.2 1395 1269 2825seleccionarseleccionar[-]
EWK 225/09 407 355 876 3.0 1690 1557 3100seleccionarseleccionar[-]
EWK 324/09 581 466 1103 4.0 1971 1850 3425seleccionarseleccionar[-]
EWK 441/09 785 633 1595 5.5 2330 2150 3459seleccionarseleccionar[-]
EWK 680/09 1234 1016 3347 7.5 3395 2381 4550seleccionarseleccionar[-]
EWK 900/09 1690 1131 3917 11.0 4415 2093 4485seleccionarseleccionar[-]
EWK 1260/09 2192 1940 6516 15.0 4285 3395 4770seleccionarseleccionar[-]
EWK 1800/09 3150 2609 10134 22.0 4605 4300 4805seleccionarseleccionar[-]

* Heat rejection at the following conditions: Tin: 35,0 ºC, Tout: 30,0 ºC, Twb: 24,0 ºC

WORKING PRINCIPLES:

Cooling towers bring a cold and dry air mass in counter-flow to hot water that comes from an industrial or air conditioning process. Part of this water evaporates, cooling the rest. The necessary heat for this is approx.597 Kcal/litre. The cold water produced is returned into the process to re-iniciate the cycle. The equipment with this evaporative refrigeration principle are very important for energy efficiency.

The difference between the required cold water temperature and the wet bulb temperature (called cooling limit distance), is significant to determine the size of the tower. The smaller the cooling distance is, the bigger the interchanging surface is needed. The limit distance must be of at least 3-4º C. In open cooling towers there is a close contact water-air, which is bigger thanks to the fill packings, that provide a big surface of exchange, improving performance and evaporation. There are different kinds of fill packing for different water quality.

  1. Sound Attenuator.
  2. Access ladder & Hand rail to the fan motor.
  3. Vibration Switch.
  4. Winter Pack (Thermostat & immersion heater)
  5. Water treathment systems (Dosing, bleed)
  6. Electric motor Frequency converters. Switch cabinets