• Compact polyester casing
  • Plastic Internals
  • Low energy consumption
  • Easy maintenance
  • Broad range. (From 4 to 500 m3/h)
Model *Dissip.
K.w.
Empty Weight
Kg.
Service Weight Kg. Fan Power
Kw.
Long
mm.
Width
mm.
High
mm.
Dim. Drawing Plane
A-Card
Technical Feat.
EWK 036 46 59 155 0.37 610 610 1590seleccionarseleccionar[-]
EWK 064 103 130 295 0.55 812 812 2020seleccionarseleccionar[-]
EWK 100 174 200 450 1.1 1020 1020 2320seleccionarseleccionar[-]
EWK 144 260 200 855 2.2 1220 1220 2620seleccionarseleccionar[-]
EWK 225 407 485 1445 3.0 1534 1534 2660seleccionarseleccionar[-]
EWK 324 581 660 1825 4.0 1825 1825 2890seleccionarseleccionar[-]
EWK 441 785 730 730 5.5 2140 2140 2940seleccionarseleccionar[-]
EWK 576 1046 850 3350 7.5 2440 2440 3425seleccionarseleccionar[-]
EWK 680 1234 1450 4700 7.5 3100 2260 3920seleccionarseleccionar[-]
EWK 900 1690 1600 6400 11.0 4125 2025 3680seleccionarseleccionar[-]
EWK 1260 2192 2400 9000 15.0 4260 3040 4060seleccionarseleccionar[-]
EWK 1800 3150 3400 13000 22.0 4100 4100 3990seleccionarseleccionar[-]

* Heat rejection at the following conditions: Tin: 35,0 ºC, Tout: 30,0 ºC, Twb: 24,0 ºC

WORKING PRINCIPLES:

Water and air are brought in close contact, for which a fan sucks in air in counter-flow to the water, as a consequence of which part of the water evaporates.

The necessary heat for this, approx.597 Kcal. For every litre of water, is taken from the circuit itself thus producing its cooling. In addition to this, the temperature drop between the hot water and the external air temperature is also used for the cooling. The efficiency of a cooling tower depends mainly on the heat exchange surface that has been assembled, on the good distribution of the water, on the amount of intake air and on the external air conditions.

The theoretical limit of cooling is the temperature in the wet bulb. This temperature can be determined on the Molier i-x diagram if the air temperature and relative humidity are known. The difference between the required cold water temperature and the wet bulb temperature (called cooling limit distance), is significant to determine the size of the tower. The bigger the cooling distance is, the smaller the tower becomes and therefore the more economical. The limit distance must be of at least 3-4º C.

  1. Sound Attenuator.
  2. Access ladder & Hand rail to the fan motor.
  3. Vibration Switch.
  4. Electric water control level in the Basin .
  5. Winter Pack (Thermostat & immersion heater)
  6. Electric motor frecuency converters.Switch cabinets.
  7. Water treathment systems (Dosing, bleed)